Skip to Main Content (Press Enter)

Logo UNICATT
  • ×
  • Home
  • Degrees
  • Courses
  • People
  • Outputs
  • Projects
  • Expertise & Skills

UNI-FIND
Logo UNICATT

|

UNI-FIND

unicatt.it
  • ×
  • Home
  • Degrees
  • Courses
  • People
  • Outputs
  • Projects
  • Expertise & Skills
  1. Outputs

Endovascular Stent-Graft Repair of True and False Aneurysms of the Splenic Artery

Academic Article
Publication Date:
2024
Short description:
Borghese, O., Pisani, A., Luparelli, A., Sica, S., Minelli, F., Donati, T., Tshomba, Y., Endovascular Stent-Graft Repair of True and False Aneurysms of the Splenic Artery, <>, 2024; 13 (April): N/A-N/A. [doi:10.3390/jcm13102802] [https://hdl.handle.net/10807/281600]
abstract:
Objective: In treatment of aneurysms (SAAs) and pseudoaneurysms (SAPs) of the splenic artery, endovascular coil embolization is the approach most commonly used as it is minimally invasive and safe. However, it carries a significant rate of primary failure (up to 30%) and might be complicated by splenic infarction. The use of stent grafts might represent a valuable alternative when specific anatomical criteria are respected. We report a comprehensive review on technical and clinical outcomes achieved in this setting. Methods: We performed a comprehensive review of the literature through the MedLine and Cochrane databases (from January 2000 to December 2023) on reported cases of stenting for SAAs and SAPs. Outcomes of interest were clinical and technical success and related complications. The durability of the procedure in the long-term was also investigated. Results: Eighteen papers were included in the analysis, totalling 41 patients (n = 20 male 48.8%, mean age 55.5, range 32–82 years; n = 31, 75.6% SAAs). Mean aneurysm diameter in non-ruptured cases was 35 mm (range 20–67 mm), and most lesions were detected at the proximal third of the splenic artery. Stent grafting was performed in an emergent setting in n = 10 (24.3%) cases, achieving immediate clinical and technical success rate in 90.2% (n = 37) of patients regardless of the type of stent-graft used. There were no procedure-related deaths, but one patient died in-hospital from septic shock and n = 2 (4.9%) patients experienced splenic infarction. At the last available follow-up, the complete exclusion of the aneurysm was confirmed in 87.8% of cases (n = 36/41), while no cases of aneurysm growing nor endoleak were reported. None of the patients required re-intervention during follow-up. Conclusions: When specific anatomical criteria are respected, endovascular repair of SAAs and SAAPs using stent grafts appears to be safe and effective, and seems to display a potential advantage in respect to simple coil embolization, preserving the patient from the risk of end-organ ischemia.
Iris type:
Articolo in rivista, Nota a sentenza
Keywords:
covered stents; rupture; splenic artery aneurysm; stent graft endovascular procedure
List of contributors:
Borghese, O.; Pisani, A.; Luparelli, Antonio; Sica, Simona; Minelli, Fabrizio; Donati, Tommaso; Tshomba, Yamume
Handle:
https://publicatt.unicatt.it/handle/10807/281600
Full Text:
https://publicatt.unicatt.it//retrieve/handle/10807/281600/536903/Endovascular%20Stent-Graft%20Repair%20of%20True%20and%20False%20Aneurysms%20of.pdf
Published in:
JOURNAL OF CLINICAL MEDICINE
Journal
  • Research Fields

Research Fields

Concepts (2)


LS4_10 - The cardiovascular system and cardiovascular diseases - (2022)

Settore MED/22 - CHIRURGIA VASCOLARE
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.4.5.0